YDL-40F Tank tal-Bitum kwadru tat-tisħin doppju tal-burner tad-diżil

YDL-40F Tank tal-Bitum kwadru tat-tisħin doppju tal-burner tad-diżil

42m³ self-heating bitumen tank with diesel burner

Formola ta' kuntatt

YDL-40F Diesel Burner Double Heating Square Bitum Tank huwa tank tal-ħażna tal-bitum ta '42m³ li jsaħħan waħdu ddisinjat għall-ħażna tal-bitum bażi, ħatt, ċirkolazzjoni interna, provvista esterna, u traċċar tas-sħana tal-pipeline.

  • Mudell: YDL-40F
  • Tip ta' prodott: Tank tal-ħażna tal-bitum tal-berner tad-diżil
  • Volum totali: 42m³
  • Metodu ta' tisħin: Tisħin dirett tad-diżil + tisħin indirett taż-żejt termali
  • Konfigurazzjoni ewlenija: Berner tad-diżil Baltur, kamra tal-kombustjoni, kolji taż-żejt termali, pompa tal-bitum iżolata, pompa taċ-ċirkolazzjoni taż-żejt termali, sistema ta' kontroll tat-temperatura, u gauge tal-livell
  • Applikazzjoni ewlenija: Ħażna tal-bitum, tisħin, ħatt, ċirkolazzjoni interna, provvista esterna, u traċċar tas-sħana tal-pipeline
Ara d-dettalji kollha

YDL-40F: Self-Heating 42 m³ Bitumen Tank — No Boiler, No Plant Room

YDL-40F is a 42 m³ square bitumen storage tank with its own Baltur diesel burner and double heating system — diesel flue tubes heat the bitumen directly while thermal oil coils hold temperature and heat-trace your pump and pipelines. It heats at 10–15 °C per hour, runs on just 8.35 kW, ships in one 40 HQ container, and needs no external boiler or plant room to operate.

  • Tisħin Doppju = Mgħaġġel + Stabbli

    Diesel flue tubes push bitumen up at 10–15 °C/h for fast heat-up; thermal oil coils then hold temperature gently — quick when you need it, stable when you do not.

  • Stazzjon tal-Bitumen Komplut f'Tank Wieħed

    Storage, heating, unloading trough, internal circulation, external supply and pipeline heat tracing — one integrated unit replaces a multi-equipment layout.

  • 8.35 kW Total Power

    Because heat comes from diesel, the whole tank — pumps, controls and all — draws just 8.35 kW. It runs where grid power is weak or expensive.

  • Iżomm is-Sħana Matul il-Lejl

    50 mm full-tank rock wool insulation limits the 24-hour temperature drop to under 10% of the difference to ambient — less reheating fuel every single morning.

Liema Tank tal-Bitum FEITENG Jaqbel mas-Sit Tiegħek?

Choose YDL-40F when you want a self-heating tank with no external boiler and diesel is available. Prefer electric heating with zero fuel handling? See the DZL electric-heated tanks. Already have a thermal oil boiler? The DL Series (30–50 m³) costs less. Need double heating in another format? Compare the YZSL double-heating tank, or the 500 m³ vertical tank for farm-scale storage.

Send us your storage volume, heating condition and unloading method — our engineers will recommend the right tank within 24 hours.

Pass 1 — Riċeviment tal-Bitum

Irċievi l-bitum mill-ħawt tal-ħatt

Base bitumen arrives via the unloading trough and the insulated 3QGB80×2-36 pump (16.8 m³/h). The same pump handles unloading, internal circulation and external supply — a DN80/DN65 three-way plug valve switches duties, so one pump does three jobs without re-piping.

Step 2 — Thermal Oil Circulation

Start oil circulation before the burner fires

The RY50-32-160 circulation pump (12.5 m³/h) moves thermal oil through the jacket and coils before heating begins. A burner–pump interlock makes the sequence physically enforced, not just a manual rule — the burner cannot fire into stagnant oil, protecting the oil from coking and the system from overheating.

Pass 3 — Tisħin Doppju

Heat through flue tubes and thermal oil coils together

The Baltur TBL 60P burner fires the jacketed combustion chamber: Φ159 flue tubes carry hot gas directly through the bitumen for fast heat-up, while the 70 mm thermal oil jacket and coils heat indirectly for gentle holding. The combination reaches up to 180 °C bitumen temperature at 10–15 °C per hour.

Pass 4 — Kontroll Awtomatiku

Issettja t-temperaturi u ħalli t-tank jaħdem waħdu

Automatic controllers watch both bitumen and thermal oil temperatures against your set upper and lower limits, starting and stopping the burner as needed. Schneider electrical components and a float level gauge with pointer display keep operation visible at a glance — no dedicated attendant required.

Step 5 — Supply and Heat Tracing

Ipprovdi l-bitum u saħħan minn qabel il-pajpijiet tiegħek

Heated bitumen circulates internally or supplies your plant externally, while the DN25 heat-tracing line feeds hot thermal oil to the bitumen pump and pipelines. Preheated lines mean no cold-start blockages — the most common cause of morning downtime at bitumen stations.

  • Square Tank Body (42 m³)

    5 mm steel plate body with 8 mm end plates on an integrated base — storage, heating and supply in one structure.

  • Baltur TBL 60P Diesel Burner

    Imported Italian burner — proven reliability and worldwide spare parts availability.

  • Jacketed Combustion Chamber

    12 mm chamber (Φ530 × 2500 mm) with 70 mm thermal-oil jacket — burner heat feeds both heating paths at once.

  • Φ159 Tubi taċ-Ċumnija

    Seamless steel tubes carry hot flue gas through the bitumen for fast direct heating.

  • Thermal Oil Coils + Circulation Pump

    Indirect heating, temperature holding and heat tracing, driven by the RY50-32-160 pump at 12.5 m³/h.

  • Pompa tal-Bitum Insulata

    3QGB80×2-36 pump, 16.8 m³/h — unloading, circulation and external supply via the three-way valve.

  • Kontroll Awtomatiku tat-Temperatura

    Dual controllers (range −200 to 450 °C) manage burner start/stop at your set bitumen and oil limits.

  • Gejġ tal-Livell bil-Float

    Il-gejġ bil-labra juri l-livell tat-tank f'ħin reali — sempliċi, robust, jinqara mill-art.

  • Insulazzjoni + Kisi

    50 mm rock wool with white corrugated steel cladding limits 24-hour heat loss to under 10% of the ambient difference.

Key Technical Parameters

Core specifications of the YDL-40F diesel burner double heating square bitumen tank.

ItemSpecification
ModelYDL-40F
Product TypeDiesel burner double heating square bitumen storage tank
Heating MethodDiesel direct heating (flue tubes) + thermal oil indirect heating
Heating Rate10–15 °C/h at 25 °C ambient
Maximum Bitumen Temperature180 °C
Total Volume42 m³
Overall Dimensions12,000 × 2,260 × 2,520 mm (including accessories), integrated base
Diesel BurnerBaltur TBL 60P (Italy)
Combustion Chamber12 mm, Φ530 × 2,500 mm, 70 mm thermal-oil jacket
Heating TubesΦ159 seamless steel flue tubes
Bitumen Pump3QGB80×2-36 insulated pump, 16.8 m³/h, 5.5 kW motor
Thermal Oil Circulation PumpRY50-32-160, 12.5 m³/h, 2.2 kW motor
Thermal Oil Working Temperature200–240 °C
PipelinesBitumen DN80/DN65 with three-way plug valve; DN25 thermal oil heat tracing
Total Installed Power8.35 kW, 380 V / 50 Hz
Insulation50 mm rock wool, 0.5 mm corrugated white steel cladding; 24-hour temperature drop ≤10% of ambient difference
ControlsAutomatic bitumen and thermal oil temperature controllers (−200 to 450 °C), Schneider components, float level gauge
Container Loading1 × 40 HQ container

YDL-40F is a storage and heating tank, not a drum decanter. Power supply, unloading conditions, heat tracing and supply connections are confirmed with your quotation.

  • Ħażna tal-Impjant tat-Taħlit tal-Asfalt

    Heated base bitumen storage with unloading, circulation and plant supply — the complete bitumen station beside your mixing plant.

  • Sistemi tal-Ipproċessar tat-Tmigħ

    Supplies heated bitumen to emulsion plants, modified bitumen units and rubber bitumen systems at the required temperature.

  • Sites Without Boiler Infrastructure

    Self-contained diesel heating and 8.35 kW power demand make it deployable on remote sites — unload the container, connect power and diesel, start heating.

Mibni minn FEITENG — 15+ Sena ta' Esportazzjoni ta' Tagħmir tal-Bitumen

Feiteng storage tanks have been delivered to the Wirtgen Group, the UK, Uganda, Mongolia and more. Every unit ships with a one-year quality warranty, online commissioning support, and engineer dispatch on request.

Bitumen storage tanks supplied to the Wirtgen Group →
Bitumen tank delivered for highway construction in Uganda →

Lista ta' Kontroll tal-RFQ

For an exact YDL-40F quotation, tell us: required storage capacity, bitumen type, unloading method, required heating rate, power supply, fuel condition, downstream equipment connection, pipeline heat-tracing requirements, container shipping limits, and site layout.

YDL-40F FAQ

What is the YDL-40F used for?

Heated base bitumen storage with unloading, internal circulation, external supply and pipeline heat tracing — for asphalt plants and bitumen processing systems.

Is YDL-40F a drum bitumen decanter?

No. It is a self-heating storage tank. For melting drum or bag bitumen, see our bitumen melting machines.

Liema metodu ta' tisħin tuża?

Double heating: the Baltur TBL 60P diesel burner drives flue tubes for fast direct heating plus thermal oil coils for indirect heating and heat tracing — up to 180 °C at 10–15 °C/h.

Can YDL-40F preheat bitumen pipelines?

Yes. A DN25 heat-tracing line supplies hot thermal oil to the bitumen pump and pipelines, preventing cold-start blockages.

Jista' jiġi ttrasportat f'Kontenitur?

Yes — the complete unit loads into one 40 HQ container and arrives on its integrated base, ready for site placement.

X'Inhuma t-termini ta' ħlas?

Usually T/T: 30% down payment, balance before delivery. L/C is also accepted. Trade terms: EXW, FOB, CFR and CIF.

Kemm idum iż-żmien tal-kunsinna?

About 20 days of production time after the down payment is received.

What warranty and after-sales support do you provide?

One-year quality warranty after delivery, with online support included. We can also dispatch engineers for installation, commissioning and operator training.